MEASUREMENT OF FLOW IN THE TANK
Based on the Terms of Reference for the Development of the Reconstruction Project of the local water supply system Međudražje in the settlement Međudražje - MZ Zavalje - City of Bihać, Center for Design and Consulting d.o.o. Banja Luka hired us to perform a 48-hour flow measurement at a pre-determined measuring point in the reservoir.
As part of the project task, among other things, it was necessary to measure the flow in order to see and assess the abundance of springs and available water, for the settlement Međudražje, and at the entrance to the reservoir from the spring.
In order to fully understand the condition of the source and the capacities currently available in the distribution of drinking water, the measurement was performed with an ultrasonic portable flow meter AQF 2000.
The ultrasonic flow meter is installed on the LŽ 80mm pipeline and programmed for a measurement interval of 1 min in a time period of 48 hours.
After the measurement, a report was made with accompanying photo documentation, a measurement diagram and an overview of the minimum, maximum and average flow at the inlet to the tank.